Polimaster Innovating radiation detection technologies since 1992

Personal Radiation Detector PM1703MA-II (PM1703®)

Category: Gamma PRDs

PRD PM1703MA-II  (PM1703®) is a brand-new personal gamma radiation detector, which has such competitive features as compact size, user-friendly interface, low-energy operation, waterproof and shockproof case combined with extremely high sensitivity.

Instrument continuously monitors the environment for radiation and alerts the user with a visual, audio and/or vibrating alarm if a radiation source is detected or any of preset radiation thresholds are exceeded.

PM1703MA-II  (PM1703®) is designed to detect, search, and locate gamma radioactive sources.

 

Learn more

Operation Principle

As well as previous well-known modifications of PRD PM1703 series (PM1703®) , PM1703MA-II  (PM1703®) continuously monitors the environment for radiation, evaluates dose equivalent rate (DER) and alerts the user with a visual, audio and/or vibrating alarm if a radiation source is detected. The readings of the instrument are displayed in counts per second for both neutron and gamma detectors and the search algorithm based on background calibration is used. The Instrument has “Mode 0…9” , which is designed to display the current level of gamma radiation background in the form of digits from 0 to 9. 

All operations history is stored in the instrument non-volatile memory (up to 1000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to the PC via USB interface. Storing data format is designed to meet ANSI N42.42.

Modifications

PM1703MA-II - basic model

PM1703MA–II BT - additionally to the functions of the basic model, is equipped with Bluetooth radio channel that enables the function of smartphones communication

PM1703MA–II MBT - differs from the basic model by extended range of DER measurement, presence of DE measurement mode and Bluetooth radio channel

Supress NORM algorithm

This algorithm allows excluding alarm signal when the natural gamma background value increases and Naturally Occurring Radioactive Materials (NORM) are detected. If NORM are detected - green indication light is given. In the case the other radionuclides types (IND, NUC, MED) are detected, red indication light and sound alarm are activated.

Options

Optionally PM1703MA-II (PM1703®) can be equipped with holster that provides additional protection for the instrument from weather, dust and occasional drops. It can be also fixed on the waist belt using belt loop.

Communication with smartphone

PM1703MA-II BT and PM1703MA-II MBT can transfer data via Bluetooth® 4.0 to smartphones based on iOS (version 7.1.1 and higher) and Android (6.0 and higher) with  Polismart® Mobile App. Free Mobile App is available for iPod® touch, iPhone®, iPad®(iOS) and for AndroidTM mobile devices and can be downloaded from App StoreSM or from Google PlayTM.

 

* iPhone, iPad touch, and the App Store logo are registered trademarks of Apple, Inc. Android and the Google play logos are trademarks of Google, Inc.

 

Application

Instruments are designed for everyday use in both indoor and outdoor environments by first responding communities: firefighters, military, emergency services, civil defense and police, customs and border patrol etc.

Standards Compliance

Storing data format is designed to meet ANSI N42.42.

Complies with ITRAP/IAEA requirements, ANSI 42.32-2016 and IEC

Specifications

Sensitivity, gamma radiation: for 137Сs, no less for 241Am, no less 100 cps per µSv/h (1 cps per µR/h)
200 cps per µSv/h (1 cps per µR/h)
Energy range from 0.033 to 3.0 MeV
Dose equivalent rate (DER) measurement range 0.1 – 70 µSv/h (10 µrem/h – 7000 µrem/h); for PM1703MA-II MBT model - 0.1µSv/h – 10 Sv/h (10 µrem/h – 1000 rem/h)
Accuracy: at 137Cs ± 30% (in range 0.1 – 70 μSv/h (10 – 7000 μR/h) ); for PM1703MA-II MBT model ± (20+(0.0025 mSv/h)/Ḣ ̇)%, where Ḣ – DER, mSv/h
Response time: in seconds 0.25
Alarm Type visual, audible and vibration
Data recording 1000 data points
Ingress protection IP65
Drop test on concrete floor 0.7 m (2.3 ft) without cover 1.5 m (4.9 ft)
Power supply One AA size alkaline or rechargeable battery 2700 mAh (recommended)
Battery lifetime: Up to 900 hours
Operating temperature -22 to +122°F (-30 to+50°C)
Humidity up to 95% at +95°F (+35°C)
Dimensions PM1703MA-II / PM1703MA-II BT - no more then 87x72x32 mm (3.43” x 2.81” x 1.25”); PM1703MA-II MBT - 99x72x36 mm (3.90” x 2.81” x 1.42” in.)
Weight no more then 7.05 oz. (200 g.)
PC communication PM1703MA-II - USB interface; PM1703MA-II BT / PM1703MA –II MBT - Bluetooth, USB interface
Operating system requirements Windows 7, Windows Server 2012 or higher.
Detector Csl(TI) scintillator

Support

Software:

PM1703MA-II/GNA-II User Software ver 2.04.40419
Size : 65.09 MB

Advertising:

PM1703MA-II/GNA-II Leaflet
Size : 1.03 MB
Algorithm of PRD selection
Size : 213.26 KB

Related products

Personal Radiation Detector PM1703MA (PM1703®) Learn more
Personal Combined Radiation Detector/Dosimeter PM1703MO-1BT (PM1703®) Learn more
Personal Radiation Detector PM1703GNA-II (PM1703®) Learn more
Personal Combined Radiation Detector/Dosimeter PM1703MO-II BT (PM1703®) Learn more

Contacts

E-mail:

info@polimaster.us

Site:

polimaster.us